VersaMax, SpectraMax 340PC384, 190, Plus 384 Microplate Readers User Guide Electromagnetic Compatibility Regulatory for Canada (ICES/NMB-001:2006) This ISM device complies with Canadian ICES-001
. spectrmax 190SpectraMax® Plus 384. 00 shipping. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. ) gap between the rear of the instrument and the wall. We enable science by offering product choice, services, process excellence and our people make it happen. The patented multichannel optical design of the SpectraMax 190 Absorbance. NO assayPage 1 ® SPECTRAmax 340PC Microplate Spectrophotometer Operator’s Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0049 Rev. ®The cell pellets were lysed with 200 mmol/L NaOH, and the iron content was determined using the ferrozine assay. The drawer will open. Bioz Stars score: 86/100, based on 1 PubMed citations. SpectraMax® 190 absorbance plate reader enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual 1-3 Introduction General Overview The SPECTRAmaxŽ 190 microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. A SOFTMAX® PRO SOFTWARE Version 5 for Mac® and Windows® User Guide Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 The VersaMax and SpectraMax 190 read 96-well microplates. SpectraMax® M3, M4, M5, and M5e Multi-Mode Microplate Readers User Guide 0112-0115 F July 2010 M3-M5e_manual. Products : SpectraMax M2/M2e reader, SpectraMax M5/M5e reader, Gemini XPS reader, FlexStation II (Obsolete), Gemini EM reader, FlexStation 3 reader. Certified SpectraMax ® M5 e-HTRF Readers The SpectraMax M5 e reader has the same perfor mance specifications as the M5 but is certified for use with Cisbio Bioassays HTRF (Homogeneous Time-Resolved Fluorescence) technology. Molecular Devices Spectramax 190 Microplate Reader Molecular Devices Spectramax 190 Microplate Reader Specifications. -Narrow bandwidths deliver increased measurement accuracy and linearity - Wavelength Range: 190 - 1000 nmSpectraMax 190: SpectraMax 340PC384: SpectraMax Plus384: VERSAmax: Vmax: Tecan: Sunrise: Trinean: DropSense96: AMBIENT TEMPERATURE STORAGE: Liconic: LPX 220 Hotel: LPX 440 Hotel: Thermo Fisher Scientific: Cytomat 10 Hotel: Cytomat 2 Hotel: Cytomat 24 Hotel: Cytomat 8 Linear Hotel: Cytomat 9 Hotel (MPH) BAR CODE. a SpectraMax 190 spectrophotometer (Molecular Devices, LLC, Sunnyvale, CA). Category 2 and 3 microplate readers use gradient heating as well. The Molecular Devices SpectraMax 384 Plus is a UV/Vis spectrophotometer and microplate reader combination for more reliable and fast data reporting with built-in cuvette port and microplate drawer. Simplify and expedite experiments with SoftMax Pro. Robust, high-value microplate readers that can run samples. SpectraMax® 340PC. Each sample has a discrete sample beam and reference beam so that each well is measured directly. TheSpectraMax® Plus384MicroplateSpectrophotometeraddstheabilitytoreadcuvettes. Temperature control and shaking come as standard. 2) All labor charges to repair the product for a period of one (1) year from the original date of delivery will be paid by Molecular Devices Corporation. Near bottom. The absorbance was measured using ELISA analytical instruments SpectraMax 190 (Thermo Fisher Scientific, CA, United States) at a wavelength of 450 nm. The SpectraMax® 190 Absorbance Microplate Reader is the ideal equipment for many life science applications including DNA analysis. Compatible with Molecular Devices SPECTRAmax 190 and 250 plate readers. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax ® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. , call 1-800-635-5577. Exceptional performance The advanced optical and electronicMolecular Devices Spectramax 190 Plate Reader used. Learn more about Services for SpectraMax® 190 Absorbance Plate Reader, Molecular Devices. Temperature control and shaking come as standard. SpectraMax 190 Register or Sign In. Detection modalities include absorbance (UV-Vis Abs), fluorescence intensity (FI), luminescence (Lumi), and all have. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-SpectraMax 190 Absorbance Microplate Reader. SpectraMax® 190 absorbance plate reader enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. For a higher degree of automation, the Automation Vendor Partners Program has streamlined the integration of our microplate reader systems with all leading partner robots. For aqueous solutions, our patented* PathCheck® sensor. Every step is optimized for data acquired from a Molecular Devices microplate reader or data imported from. The SpectraMax 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications, especially DNA analysis. Features: Absorbance, Fluorescence and Luminescence plate reader for all microplate formats. You can also contact Technical Support by email. ability to detect 16 ng/well of DNA and to quantitate 50 ng of . Temperature uniformity within the microplate may vary depending on the type of microplate used. For colony-forming assays, stable Caki-1 and 796-O anti-miR-155/TCL6-OE cells and their respective control cells were plated at a low density onto 10-cm dishes (1,000. Wavelength selection Monochromator tunable in 1 nm increments. Examples: fiPress carefully to engage,fl fiDo not press down. The ability to detect 16 ng/well of DNA and to quantitate 50 ng of DNA provides the same sensitivity as a spectrophotometer. ; The top 3 importers of Spectramax are India with 365. Overview. The instrument has a pathlength correction feature. In manufacturing DNA/RNA-synthesizers for universities, hospitals and private companies all over the world, the group relies on the SpectraMax 190 Absorbance Microplate Reader. Description Control Panel Cuvette Chamber Back Panel Microplate Drawer The Control Panel TEMP on/off TEMP Figure 1. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. The Molecular Devices SpectraMAX absorbance microplate readers mimic a dual beam spectrophotometer with a patented multichannel optical design. The plates were then read on a SpectraMax 190 reader (Molecular Devices) at 450 nm. EXPERIENCED-We have been building labs, equipping labs, and supplying lab equipment parts and service for over 20 years. SpectraDrop High-Throughput Screening (HTS) Kit. SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual 1-3 Introduction General Overview The SPECTRAmaxŽ 190 microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. TheSpectraMax®Plus384addstheabilitytoread cuvettes. ®Introducing the Most Advanced LED Grow Light. 5 mm (bottom read) Beam diverges to focal spot near bottom of well. Molecular Dynamics Phosphorimager Model 425F + details. ATP standard curves read on SpectraMax microplate readers. SpectraMax 190: Located in the back of lab 302 . and planktonic cells, was measured at 595 nm in a spectrophotometer (SpectraMax 190, Molecular Devices, Sunnyvale, CA, USA). HTRF is a proprietary time-resolved fluoresce nce technology that overcomesThe VersaMax and SpectraMax 190 read 96-well microplates. The SpectraMax® 190 UV-Vis Microplate Spectrophotometer from Molecular Devices is ideal. The protein concentration was quantified using Bradford reagent (Sigma–Aldrich, Shanghai, China). Molecular Devices Spectramax 190 Absorbance Microplate Reader. 1) Turn on the power switch of the SPECTRAmax 190 (located on the back panel). Pre-owned. Perkin Elmer 1420 Victor 3V + details. Microplate Readers Molecular Devices SpectraMax M2 Multimode Plate Reader. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Wavelength range 190 nm to 850 nm. ” SPECTRAmax 340PC Microplate Spectrophotometer Operator’s Manual 1-3 Introduction General Overview The SPECTRAmax ® 340PC incorporates a holographic grating monochromator which allows you to specify a precise wavelength, from 340 nm to 850 nm, for the absorbance maximum of your sample. Sale Price: $12,125. Monochromator, tunable 1. To provide access to disconnect power from the instrument, maintain a 20 cm to 30 cm (7. 5. #3635 or Greiner cat. 0200-6263. Molecular Spectramax 190 Microplate Reader. Prepare your i3/i3x instrument for shipment. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. TRIAX 180/190 TRIAX 320 TRIAX 550 Part Number 81034 Issued February 1999. Perkin Elmer HTS 7000 Bio Assay ReaderFigure 1. Molecular Devices Spectramax 190 Microplate Reader Our Price: $6,185. please click here. GM2000 Register or Sign In. For very concentrated samples, use a minimumThe SpectraMax Plus 384 Microplate Reader for absorbance measurements from 190 to 1000 nm quickly for samples in test tubes, cuvettes, and 96- or 384-well microplates. The control panel consists of a 2-x-20-character LCD and eleven pressure-sensitive membrane keys that can be used to control some functions of the instrument. 00 . SpectraMax® M2 Multi-Mode Microplate Reader MLDVM2 SpectraMax® M2e Multi-Mode Microplate Reader (top and bottom reading) MLDVM2E SpectraMax® M3 Multi-Mode Microplate Reader MLDVM3 Ordering information VWR cat. 315 can't find zero order. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid- Tecan Infinite M200 PRO Plate Reader-Tecan Mono Absorbance, Tecan Luminescence, Tecan PMT Enhanced -used system- includes Tecan system dongle. SpectraMax Spectrophotometers for UV-Vis Absorbance Detection. 1. Add to cart. it should turn freely, without any friction. . Perform the following steps to install the drivers: Start > Control Panel > System. The SpectraMax ABS readers use a grating monochromator to select the exact wavelength needed . Exceptional performance SoftMax® Pro Software for Windows 10 and 11 is designed to provide the simplicity, flexibility and power required for advanced data analysis. . x Microplate Data Acquisition & Analysis Software for Windows. S. ) Turn on the SpectraMax L and connect the computer to the SpectraMax L using the USB cable. The SpectraMax 190 reader is the tool for DNA analysis. The Gemini XPS Reader has dual monochromators that allow users to utilize new and novel dyes without purchasing expensive filter sets. Ends from. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. Performance Specifications . . 38 Dimension® EXL™ with LM Air Filter Monthly Maintenance. For very concentrated samples, use a minimumSamples were incubated at 100°C for 3 min and left to cool, then 50 μL of 0. SpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Molecular Dynamics Phosphorimager Model 425F + details. This version is compatible with the following instruments: SpectraMax® Mini Multi-Mode Microplate Reader (software version 7. Molecular Dynamics Phosphorimager Model 425F + details. The SpectraMax 190 reader can be integrated with Molecular Devices’ StakMax Microplate Stacker in a matter of minutes and begin reading microplates with seven mouse clicks. 0112-0174C 3 Contents SafetyInformation 4 Warnings,Cautions,Notes,andTips 4 Chapter1:Introduction 7 InstrumentFeatures 8 ComputerIntegration 9 PMTTechnology 9SpectraMax 190 Microplate Reader Plate olvasók -Abszorbancia A microplate reader for exploring the mysteries of life. Also review the Maintenance and Troubleshooting chapter of the user guide for your model plate reader. 312 gain calibration failed. NOTE: Limited support and literature is available for the SpectraMax 250 due to the senescence of the product. ATP concentration (M) Average RLU SpectraMax L SpectraMax i3x (cartridge) SpectraMax Mini SpectraMax iD5 SpectraMax i3x (onboard) SpectraMax M5e The SpectraMax ® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. The OD values of this chromogenic enzymatic reaction were read on a microplate spectrophotometer (Spectramax 190, Molecular Devices Corporation, Sunnyvale, CA) at 450 nm within 30 min after adding the stop solution. spr * SpectraMax i3(x) SpectraTest ABS2 v1. Wavelength accuracy ±1. Example: [Drawer]. The multi-channel design truly mimics a dual-beam spectrophotometer. Molecular Devices SpectraMax 340PC Microplate Spectrophotometer $ 3,500. Italic and boldface type are used for emphasis. ATP standard curves read on SpectraMax microplate readers. Molecular Devices SpectraMax ABS Plus Microplate Reader; Related products. 验证检测 SpectraMax 190 的工作状态。 堆板机、机械臂一体化整合 SpectraMax 190 可以在几分钟内整合到 Molecular Devices 的 StakMax 堆板机上。为了实现更高程度的自动化,自动化供应商 合作伙伴已经把我们的酶标仪系统和所有主要合作伙伴的机械臂 进行了整合。 SpectraMax Multi-Mode Reader SpectraMax 340. See More Information. The absorbance of the reaction mixture was recorded at 593 nm (SpectraMax 190, Molecular devices) after 5 min. The instrument is designed to regulate the temperature of the plate chamber from 5°C above ambient to 45°C. Part # 0112-0085 Rev. Additional accessories are available including the µMax Low Volume Plate, standard validation tools, and 21 CFR Part 11 Compliance tools. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. Wavelength Accuracy: < ± 2. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. The ability to detect 16 ng/well of DNA and to quantitate 50 ng of DNA provides the same sensitivity as a spectrophotometer. VersaMax, SpectraMax 340PC384, 190, Plus 384 Microplate Readers User Guide Electromagnetic Compatibility Regulatory for Canada (ICES/NMB-001:2006) This ISM device complies with Canadian ICES-001. Fluorescence Microplate Reader Comparison Chart. Protein concentrations were calculated using. 0 out of 5 $ 4,499-20%. The SpectraDrop Microplate incorporates a specially designed adapter and a slide pair whose optical clarity allows measurements in absorbance and. Unit Cables SpectraMax 190 User’s Manual and SoftMax Pro USB data loggers EBI 300 TE and EBI 300 TH Logger is user-programmable via free online configuration SpectraMax® 190 absorbance plate reader enables dataSpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. 5 mM −1 ∙cm −1) in a SpectraMax 190 plate reader (Molecular Devices). 2 or higher, standard edition only, no GxP) VersaMax™ Microplate Reader (Serial numbers begining with BNxxxxx and BNRxxxxx are supported) SpectraMax® 190 Absorbance Microplate Reader (Serial numbers. The patented multichannel optical design. With optimized reagents and the industry-leading data acquisition and analysis tool SoftMax® Pro 7 Software, the SpectraMax iD3 allows you to customize your workflow to. Select the Driver tab and click Update Driver. Molecular Devices SpectraMax 190 and SoftMax Pro6. Service parts for these models are not being produced and are no longer in stock. Molecular Devices technical support. Protein concentrations were calculated using polynomial 2nd analysis from the protein standards. SPECTRAmax PLUS 384 Microplate Spectrophotometer Operator’s Manual 1-3 Introduction General Overview The SPECTRAmax™ PLUS 384 microplate spectrophotometer provides rapid and sensitive UV/VIS measurements of a variety of analytes including specific proteins, nucleic acids, and other molecules across a wide range of concentra-tions. The dual-scanning capability can also be used to determine excitation and emission settings for new fluorescent probes. Sample extracts (10 μl) were mixed with 190 μl of diluted ABTS solution in 96-well plates and incubated for 7 min at 37°C in the dark. The absorbance was determined at 510 nm using a SpectrMax 190 plate reader (Molecular Devices, CA, USA). Robust. ®The SpectraMax 190 Microplate Reader's optical system is built around a monochromator, allowing the selection of up to six wavelengths at a time for absorbance detection in the UV-Vis wavelength range (190 nm - 850 nm). Perkin Elmer 1420 Victor 3V + details. $500. The Gemini EM Reader with dual monochromators allows researchers to try new and novel dyes without having toThe SpectraMax ® iD5 Multi-Mode Microplate Reader is the complete laboratory solution to help you increase your research capabilities and. The SPECTRAmax ® 190 microplate spectrophotometer is the tool you need for DNA analysis. Biotek PowerWave XS Microplate Reader BioTek Synergy HTX Microplate Reader - Absorbance Only BioTek ELx808 Ultra Microplate Reader - Absorbance OnlyThe SpectraMax® Quant™ dsDNA Assay Kits are designed for fluorescence-based dsDNA quantitation across a broad range of concentrations. Note: Remove dust from all reusable filters by washing with water and air drying or by using a vacuum cleaner. The patented multichannel optical design of the SpectraMax® 190 Absorbance Microplate Reader mimics a dual beam spectrophotometer, measures each sample in the plate. For more information, please visit us at would like to show you a description here but the site won’t allow us. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid- The SpectraMax® M Series Multi-Mode Microplate Readers measure UV and visible absorbance, fluorescence, luminescence, fluorescence polarization, TRF and HTRF. Robust, high-value microplate readers that can run samples based on pre-defined protocols and standard filter modes cover the entire visible range for a variety of assays. Temperature control and shaking come as standard. Cell Apoptosis Assay Following treatment, the apoptosis rate of H9c2 cells was analyzed by flow cytometry analyses using the Annexin V-FITC/PI Cell Apoptosis Detection Kit (Dojindo. Molecular Devices SpectraMax ABS Plus Microplate Reader. Molecular Devices SpectraMax 340PC384 Microplate Reader $ 4,000. The ABS reader ranges from 340–850 nm in wavelength and the ABS Plus reader ranges from 190–1000 nm, which is equivalent to having 510 or 810 free filters, respectively. Molecular Devices Spectramax 190 Plate Reader used. For very concentrated samples, use a minimum volumeSpectraMax® 190. Quantification of protein and nucleic acid components in the crude exopolysaccharides was performed by measuring the UV spectrum from 200 to 400 nm using a quartz cuvette with a 1 cm path length using a SpectraMax 190 Microplate Reader (SpectraMax M2 e, Molecular Devices, Sunnyvale, CA)This tunable visible absorbance reader is for 96- and 384-well microplates and acquires data in endpoint, kinetic, and spectral scan modes using wavelengths from 340-850 nm, tunable in 1 nm increments. Flavonoid Compositions Analysis . Offer Ends In: 44 Days 19: 59: 40. Italic and boldface type are used for emphasis. Trunk injection is a crop protection strategy. Fresh porcine aortic valve cusps were supplied by St. Rigging/Removals Loading, Rigging, and Freight are at buyers expense. 1. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-This UV-visible absorbance microplate reader provides ultrafast, full spectral range detection for cuvettes, 96-well, and 384-well microplates, with the only temperature-independent method for pathlength correction. Day length. Free shipping. 0) at 37 °C, fluorescence intensity was recorded on a Spectramax M5 Multimode plate reader. Examples: “Press carefully to engage,” “ Do not. The change in absorbance was followed on either a Spectrmax 190 or Spectrmax Gemini XS plate reader (Molecular Devices Corp. Page 6 SpectraMax Plus384, 190, 340PC384, and VersaMax Installation Guide Connecting Instrument Cables The power cord and USB cable connect to the ports on the rear of the instrument. i Molecular Devices Corporation is pleased to publish this new edition of our Applications Guide. Standards were plotted using a log-log curve fit in SoftMax Pro Software. Exceptional performancePreconfigured protocols and custom assay workflows simplify microplate data acquisition and analysis. 314 low lamp level warning. The SpectraMax 190 reader is the tool for DNA analysis. All experiments were repeated at least three times, and data were obtained in triplicate. Methods. SpectraMax 190 and VersaMax readers can accommodate standard 96-well and strip-well microplates. Patient samples were diluted 1:100, except for patients with CML for whom a dilution of 1:300 was used. STAKMAX. Fluorescence Microplate Reader Comparison Chart. Manufacturer: Molecular Devices; Model: SpectraMax 190 * Wavelength Selection Monochromator, tunable 1. The SPECTRAmax 340PC can mea- SPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual 1-3 Introduction General Overview The SPECTRAmaxŽ 190 microplate spectrophotometer provides rapid and sensitive measurements of a variety of analytes across a wide range of concentrations. After 1 h of incubation, the absorbance of each well was measured at A450 nm using a SpectraMax microplate reader (SpectraMax 190, Molecular Devices, USA). Fully tested with Validation and Warranty. Not all manufacturers microplates are the same with regard to. 118 Gemini XPS Fluorescence Microplate Reader . 사용이 편리하고 견고한 생명과학 연구, 신약 개발, 개발, Bioassay용 assay. 단일 튜브 디스펜싱에서 전체 96 및 384 well 플레이트세척까지 간소화된 Microplate 세척입니다. 001 photometric resolution, xenon flash lamp, selectable optimum wavelength by viewing the complete spectrum of the sample, Pathcheck sensor can expand the dynamic range of. Perkin Elmer 1420 Victor 3V + details. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-The change in absorbance was followed on either a Spectrmax 190 or Spectrmax Gemini XS plate reader (Molecular Devices Corp. The standard curve was made using iron (II) sulphate solution (40–0. Perkin Elmer HTS 7000 Bio Assay ReaderSpectraMax 190 Absorbance Microplate Reader with laptop and software Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. The instrument reads any standard cuvette, microcuvette, test tube or 96- and 384-well standard or UV transparent microplate over a full 190 to 1000. SpectraMax 190 Absorbance Microplate Reader from Molecular Devices LLC. Evaluation of Hepatitis B Virus DNA. Italic and boldface type are used for emphasis. 340PC; 340PC384 User guide; 340PC384 Installation guide; 340; SpectraMax Line. Ultraviolet transparent multiwell plates from Greiner; Highly recommended for measurements of DNA and protein concentrations at 260 nm or 280 nm, respectively; No need for expensive and fragile quartz glass plates; UV transparent to 200 nm;We used three technical replications for each biological replication and measured absorbance at 595 nm using a SpectraMax 190 spectrophotometer (Molecular Devices, LLC, Sunnyvale, CA). Molecular Devices Spectramax 190 Plate Reader used. SpectraMax® M-Series Readers, SpectraMax® Paradigm® Systems, FlexStation® 3 Systems. Narrow bandwidths deliver increased measurement accuracy and linearity over the widest range of assays, including. The multichannel design for 96-well microplates uses separate sample and reference beams for each. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-The SpectraMax® M Series Multi-Mode Microplate Readers are modular and upgradeable with a wide range of high performance capabilities ideal for life science research and drug discovery screening SoftMax® Pro 7. Compatible with Molecular Devices SPECTRAmax 190 and 250 plate readers. SpectraMax 250 User. Molecular Devices Spectramax 190 Plate Reader used. !Pathchecklm1000. 3 mm. TheSpectraMax®190MicroplateSpectrophotometer,SpectraMax®340PC384Microplate Spectrophotometer,andVersaMax™MicroplateSpectrophotometerproviderapidandsensitive. Theseinstruments TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate spectrophotometersproviderapidandsensitivemeasurementsofavarietyofanalytes acrossawiderangeofconcentrations. Enables data acquisition in endpoint, kinetic, and spectral scan modes at. According to the manufacturer, the sensitivity of this assay is 5 ng/ml and has less than 1% cross. Keywords: spectramax m2 systems, spectramax m2e systems, spectramax m2/m2e readers, pathcheck sensor, spectratest abs1 absorbance, stakmax stacker Created Date:. Since this is an older reader, we recommend that new users choose our newer model i3 reader. The . ; Page 2 1) All labor charges to repair the product for a period of one (1) year from the original date of delivery will be paid by Molecular Devices Corporation. 7°C and the bottom to 36. Examples: “Press carefully to engage,” “ Do not. 194 Joseph St, Victoria, BC V8S 3H5 is currently not for sale. The resulting absorbance levels were then quantified spectroscopically at 560 nm using a SpectrMax® 190 spectrophotometer . The SpectraMax Plus 384 reader is equipped with an innovation patented by Molecular Devices, the PathCheck® sensor, which measures the depth of a sample in a microplate by optical path length. 8 in. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. Molecular Devices Spectrophotometer Spectra MAX 190. No accessories are needed and SoftMax® Pro. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-* dsDNA sensitivity specified for the following instruments: SpectraMax® 190 Readers, SpectraMax® Plus384 Readers,. TheSpectraMax®340PC384,SpectraMax®190,andVersaMax™microplate spectrophotometersproviderapidandsensitivemeasurementsofavarietyofanalytes. When the user applies a set temperature of 37°C, the top is heated to 37. spr SpectraMax iD5 SpectraTest ABS2 v1. Perkin Elmer 1420 Victor 3V + details. It measures the optical density (OD) of samples in 96-well SpectraMax® 190 Absorbance Plate Reader, Molecular Devices Microplate Readers Enables data acquisition in endpoint, kinetic, and spectral scan modes at wavelengths across the UV-visible wavelength range, with the only temperature-independent method of pathlength correction. Rose Bengal is a photoreactive compound with its absorbance peaks at 258 nm, 519 nm, and 562 nm Citation 33. SpectraMax Gemini EM & FLEXstation (bottom read) 1. US. 0 out of 5 $ 9,995 $ 9,495. The final value was expressed as ng/g protein. The contents of the wells in a microplate can be mixed automatically by shaking before each read cycle, which makes it possible to perform kinetic analysis of solid-Tumor cells were plated onto 96-well plates (500 cells/well), and 10 µl of Premix WST-1 Cell Proliferation Assay System (Takara Bio Inc. The VersaMax and SpectraMax 190 read 96-well microplates. 1. 1step assay with SpectraMax microplate readers. Web Information The Spectramax 190 absorbance microplate reader utilizes a patented multichannel optical design to simulate a dual beam spectrophotometer to help eliminate errors through the usage of a dual fiber optic exposure. The sensitivity of this assay was 250 pg/mL, and the intra. The SpectraMax® 190 Absorbance Microplate Reader is the ideal equipment for many life science applications including DNA analysis. 7°C (gradient heating design). The SpectraMax® 190 spectrophotometer is ideal for most life science applications, especially DNA analysis. Step 3. no. Concentration curves were run in triplicate and IC 50 values were calculated by following the 4-parameter logistic curve fitting equation. Molecular Dynamics Phosphorimager Model 425F + details. Figure 1. 滤光片型光吸收微孔板读板机(酶标仪),简单易用,性价比高,检测结果精确. Molecular Devices SpectraMax 190 Microplate Reader This is a Nice Used Plate is Not Included. SpectraMax iD3 reader. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. Not all manufacturers microplates are the same with regard to design, mate- rials, or conÞguration. SOFTmax PRO. 0 nm increments * Wavelength Bandwidth 2 nm * Wavelength Accuracy < ± 2. The SpectraMax 190 Reader is the tool for DNA analysis. After treatment with paramylon or lipopolysaccharide for 24 h, 10 μL of cell counting kit reagents was added to the cells. The SpectraMax i3x reader has variable bandwidth for fluorescence and luminescence, and you are able to choose either 9nm or 15 nm for excitation and either 15 nm or 25 nm for emission. ¨The absorbance was measured by an enzyme-labeled instrument (SpectraMax 190, Shanghai, China) at 482 nm. Type: Clear: Add to Cart. used. ; India imports most of its Spectramax from United States, China and Austria and is the largest importer of Spectramax in the World. The statistical significance of the differences between the control and experimental results. Offer Ends In: 38 Days 16: 07: 54. ATP concentration (M) Average RLU SpectraMax L SpectraMax i3x (cartridge) SpectraMax Mini SpectraMax iD5 SpectraMax i3x (onboard) SpectraMax M5eThe SpectraMax ® iD3 Multi-Mode Microplate Reader is the cornerstone of a complete laboratory solution to help you expand the boundaries of your research capabilities. spr SpectraMax iD3 SpectraTest ABS2 v1. 专为科研检测平台量身打造的灵活且强大的小型微孔板读板机(酶标仪),具备终点法和动力学检测模式,标准配置6块滤光片,覆盖蛋白定量、细胞活力、农药残留、ELISA实验等. SpectraMax L Microplate Reader is a sensitive luminometer with programmable injector options that measures flash and glow luminescence assays, including dual luciferase. 2 nm * Wavelength Range 190 – 850 nm * Photometric. The SpectraMax 340PC 384 and SpectraMax Plus 384 read both 96-and 384-well microplates. After this date, all service and support will be on a reasonable effort basis At this time, we are happy to help you upgrade to the SpectraMax® ABS or ABS Plus Microplate Readers which containSpectraMax Readers have the most complete level of product validation and compliance. 1. SpectraMax Plus384, 190, 340PC384, and VersaMax Installation Guide Author: Molecular Devices Subject: Installation Guide Keywords: SpectraMax Versa and others Detection Platform Created Date:The Molecular Devices SpectraMax M3 Multi-Mode Microplate Reader is a dual-monochromator, multi-detection microplate reader with full spectral range detection for cuvettes and 6-, 12-, 24-, 48-, 96-, and 384-well microplates. It measures the optical density (OD) of samples in 96-wellSPECTRAmax 190 Microplate Spectrophotometer Operator™s Manual vii Conventions Used in this Manual The names of keys that appear on the SPECTRAmax 190 control panel are shown in boxed Helvetica type. 0200-0729. Wavelength Bandwidth. US. polynomial 2nd analysis from the protein standards. SpectraMax 190 Absorbance Microplate Reader by Molecular Devices®. Perkin Elmer 1420 Victor 3V + details. The SpectraMax 190 has a multichannel design for 96-wellSpectraMax and VersaMax Plate Readers Operator’s Manual — 0112-0126 Rev A SpectraMax Plus 384 SpectraMax 190 SpectraMax 340PC 384 VersaMax Microplate Spectrophotometer Operator's Manual Molecular Devices Corporation 1311 Orleans Drive Sunnyvale, California 94089 Part # 0112-0126 Rev A. Method 66DNA Analysis on the Molecular Devices Spectramax Plus and Spectramax 190 microplate readers Quick Reference Guide Section A: Plate Materials A UV transparent microplate is required for. Molecular Devices’ PathCheck® sensor technology. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. 5 - 2. Microplate Readers Biotek ELx808 Microplate Reader Absorbance. i3. ISM Equipment Classification (Group 1, Class A) This equipment is designated as. See SpectraMax® Microplate Reader User Manual Download Page. Capable of detecting DNA down to 25 ng per well, this model gives users. Pre-owned. The PathCheck sensor can extend the instrument linearity by a factor of three or more. ) Turn on the SpectraMax L and connect the computer to the SpectraMax L using the USB cable. ISM Equipment Classification (Group 1, Class A) This equipment is. The information is below the horizontal line. The multi-channel design truly mimics a. At that point halfway up the maximum transmittance value, the total width (nm) of the. The VersaMax and SpectraMax 190 read 96-well microplates. • Trained in running Qbit real-time assay, 6 plex. 0. The plate. Colorimetric reaction was stopped by adding 2 NH2SO4. The protein concentration was measured by an enhanced BCA protein assay kit (Beyotime; Nanjing, China). 0200-7027. The absorbances were measured at 450 nm and 630 nm on a SpectraMax 190 microplate reader (Molecular Devices) or an SH-1200Lab microplate reader (Corona Electric). In the control group, the flavonoid solution was. SpectraDrop Micro-Volume Refills, 24-Well Bottom Slides. Molecular Devices Spectramax GeminiXS Plate Reader GeminiXS SpectrMAX , used, nice, excellent condition- inquire for further details + details. We will match our competitor's price! The SpectraMax® 190 Microplate Reader from Molecular Devices is ideal for UV-Vis life science applications, especially DNA analysis. to 500 nm) spectroscopy (SpectrMAX 190; Molecular. The absorbance was measured at 620 nm using the microplate spectrophotometer (Spectramax 190, Molecular Devices Corporation, Sunnyvale, CA). 2. Double-click the unknown device with the yellow warning icon. The SPECTRAmax 190 is equipped with an 8-pin DIN RS-232 serial port through which a computer can communicate with and control the instrument. See More Information. The minimum detectable concentration of this assay was 0. SPECTRAmax PLUS 384 Microplate Spectrophotometer Operator’s Manual vii Conventions Used in this Manual The names of keys that appear on the SPECTRAmax PLUS 384 control panel are shown in boxed Helvetica type. . 0 nm * Wavelength Repeatability ± 0. For a complete list of the instruments supported by this release of the SoftMax Pro Software, see Supported Instruments on page 111.